← Quantum algorithms & complexity
A17IncrementalImproved

Quantum state certification with local measurements

In other catalogues

Not found in other catalogues.

Given a full classical description of an arbitrary reference state σ\sigma and copies of an unknown NN-qubit state ρ\rho, determine the optimal copy complexity of testing ρ=σ\rho=\sigma versus ∥ρ−σ∥1≥ε\|\rho-\sigma\|_1\ge\varepsilon, with success at least 2/32/3, using adaptive single-qubit Pauli measurements and no entangling measurements within or across copies. Seek matching instance-dependent bounds and the accompanying classical running time.

Definition

Quantum state certification asks to test whether copies of an unknown state equal a known reference state or are far from it in trace distance. A full reference-state description can itself be exponentially long in NN; computational costs must count its input length. Rank, spectrum and the reference eigenbasis relative to the allowed local measurements can matter. This concrete certification target is distinct from estimating an unknown state's spectral functional or learning many observable expectations.

Haah, Harrow, Ji, Wu and Yu establish sample-optimal tomography bounds in their collective-measurement model, IEEE Trans. Inf. Theory 63 (2017), arXiv:1508.01797.

Progress

  • In August 2026, Wang gave a framework with nearly tight lower bounds for entropy, closeness and spectrum estimation and for rank testing (arXiv:2608.02600); its 8 September 2026 v3 adds Schmidt-rank and MPS testing and is retitled as a unified complexity framework for quantum property testing; v4 appeared on 29 October 2026.
  • In August 2026, Acharya, Dharmavarapu, Liu and Yu nearly determined mixedness testing under single-qubit Pauli measurements, with Θ~((10)N/ε2)\widetilde\Theta((\sqrt{10})^N/\varepsilon^2) copies (arXiv:2608.18839); their 21 September 2026 v2 adds fixed-Pauli-protocol bounds; v4 (4 November 2026) adds deterministic-protocol results. The maximally mixed reference is a benchmark, not a solution for every reference state or measurement trade-off.
  • In August 2026, Stempin, Llorens and Huber disproved the fractional-colouring conjecture proposed as a route to universal triply efficient Pauli shadow tomography (arXiv:2608.20113). This rules out that route, not every possible algorithm.
  • Between 4 and 9 September 2026 (v1), two adjacent tomography benchmarks appeared. Keskin, Luo, Majid and Radzihovsky claim a lower bound which, with the earlier upper bound, gives tight arbitrary-state copy complexity Θ(max⁡{d3/(kε2),d2/ε2})\Theta(\max\{d^3/(\sqrt{k}\varepsilon^2),d^2/\varepsilon^2\}) for every kk and sufficiently small ε\varepsilon, when measurements act on at most kk fresh copies, with classical adaptivity but no quantum memory between blocks (arXiv:2609.05718). Nayak and Zhou claim the rank-rr refinement Θ((dr/ε2)max⁡{1,r/t})\Theta((dr/\varepsilon^2)\max\{1,r/\sqrt{t}\}) with at most tt jointly measured copies, for sufficiently small error and constant success probability (arXiv:2609.10514). These permit entangling measurements and reconstruct an unknown state; neither settles arbitrary-reference certification with single-qubit Pauli measurements.
  • On 9 September 2026, Zhang et al. gave shallow phase shadows for stabilizer-state fidelity estimation (arXiv:2609.10408). The constant-depth implementation assumes all-to-all connectivity, mid-circuit measurements and classical feedforward; without auxiliary systems the stated depth is logarithmic. Its entangling readout and restricted observables do not remove the measurement restrictions of the statement or the earlier obstruction to a universal Pauli-shadow route.

Previous progress

  • Preprint claimed progress

    Matching tomography lower bound for adaptive fresh-copy blocks with no quantum memory between blocks; entangling block measurements are allowed.

    Source · v1 · 2026-09-04
  • Preprint claimed progress

    Claimed optimal rank-dependent tomography rate with bounded-copy joint measurements; not single-qubit Pauli certification.

    Source · v1 · 2026-09-09
  • Preprint claimed progress

    Stabilizer-fidelity estimation with entangling readout; constant depth uses all-to-all connectivity, auxiliary resources, mid-circuit measurements and feedforward.

    Source · v1 · 2026-09-09
  • Preprint claimed progress

    Unified lower-bound framework for spectral-functional estimation and rank/Schmidt-rank/MPS testing (v3); task-specific hypotheses still apply.

    Source · v3 · 2026-09-08
  • Preprint claimed progress

    Nearly tight single-qubit Pauli mixedness-testing copy complexity; arbitrary-reference certification remains a separate target.

    Source · v1
  • Preprint claimed progress

    Counterexamples close the proposed universal fractional-colouring route to triply efficient Pauli shadow tomography.

    Source · v1

Related questions & consolidated subproblems

References

Author-reported provenance

These are attributed disclosures, not independent determinations of authorship or proof correctness.